Industrial Steam Boiler for Food Plants

Food-grade steam boiler: provides clean steam for cooking, sterilizing, CIP, and heating.

jacketed steam boiler

Feature

  1. STM-101 — 100 kg/h: Electric boiler. Small plant.
  2. STM-001 — 1,000 kg/h: Gas-fired. Mid-scale.
  3. STM-201 — 5,000 kg/h: Oil/gas dual. Industrial.
  4. Typical values throughout — configured to your line requirements.

Sample

Sample output from the Industrial Steam Boiler. Ask us for real production photos matched to your exact product and capacity.

emergency

We are Here for You. Contact us Now

⏰ 7 * 24 Support
🔧 Remote Support
🌍 Global Coverage

Parameters

Food-grade steam boiler: provides clean steam for cooking, sterilizing, CIP, and heating. 100-5,000 kg/h. Gas, oil, or electric. Low NOx burner.

Model Range

ModelCapacityConfiguration
STM-101100 kg/hElectric boiler. Small plant.
STM-0011,000 kg/hGas-fired. Mid-scale.
STM-2015,000 kg/hOil/gas dual. Industrial.

Typical values — each model is configured to your product, cut size, and line speed.

Where It's Used

Food plants supplying process steam to cookers, dryers, and CIP. For the full range, see the processing hub.

FAQ

Add up the steam consumption of every user: cookers, dryers, sterilizers, CIP heat exchangers, and heating jackets, then apply a diversity factor because not all run at peak together. The range covers 100 to 5,000 kg/h. Size for the winter and peak-season case, not the average day, and leave margin so the burner is not cycling constantly. Send the user list and we run the calculation.

The wetted parts are stainless steel and the steam side runs without chemical treatment contacting the product side, which is what culinary-grade service means in practice. That matters where steam injects directly into kettles or touches product surfaces. For indirect duty through heat exchangers the specification is simpler. We configure the plant against your culinary steam requirement at order stage.

Gas generally gives the cheapest running cost where supply and pressure are reliable, and it serves the whole capacity range. Electric is the cleanest option, with no on-site emissions and no flue, but suits plants limited to around 500 kg/h. Oil, or dual-fuel oil and gas, covers sites without dependable gas. We compare your local fuel prices against the load profile before recommending.

Softened water is the minimum for the feed, with reverse osmosis water specified for electric boilers, and automatic blowdown controls dissolved solids in the vessel. Skipping treatment is what shortens boiler life: scale insulates the heating surface and chloride attacks it. A monthly water quality test is the routine that catches drift. We provide the feedwater specification your plant should hold to.

Expect combustion efficiency around 92 to 95% with an economizer fitted, and a condensing option pushing higher where return water is cold enough to exploit it. Monitoring covers pressure, temperature, water level, and burner status on the panel, with feedwater and blowdown logged. Those records are what let you verify fuel per tonne of steam and spot efficiency loss between services.

Yes. We provide installation and commissioning support, and 12 months of after-sales service, including spare parts help and technical response.

TAKE THE FIRST STEP. WE WILL DO THE REST.
Scroll to Top
small c popup.png

Get Your Production Line Plan Now

It will be sent to Boss and sales team directly.